NUE 599
Final Year Project
4
Course Outline
A problem, limited and well defined in scope and adapted to the topics of this undergraduate
programme, is to be solved by the student on his own responsibility in a definite period of
time, under the supervision of an instructor. This provides the opportunity to apply
engineering knowledge and methods in a practical way, e.g. measurements in connection with
calculations, programming applications. The problem selected should have interdisciplinary
aspects. It is recommended that the project work be carried out in an industrial organization
or research institute, with the participation and supervision of the university. If nuclear
facilities are available, the project work could be performed there. The results should be
presented as a written report. One project per student.
Minimum Academic Standards
Equipment
Radiation protection and measurement
Radiation Detector (PRD); Gamma Neutron Type
Dossimeter; electronic type (EPD)
Radioisotope identifier; handheld type
Survey meters; general purpose type
Radiation portal monitor; pedestrian and luggage type
Nuclear Security Laboratory
Model 701 series isotope identifier
Meters and scanners
Physical protection systems analytical tool
Nuclear power plant simulation Laboratory
Three-key master generic PWR simulation system
Dinco software
Prism Software
MATLAB
Staffing
Academic Staff
The NUC guidelines on staff/student ratio of 1:15 for Engineering and Technology
departments shall apply. However, there should be a minimum of six full-time equivalents
of Staff in the department. There is need to have a reasonable number of Staff with doctoral
degrees as well as sufficient industrial experience. With a minimum load of 15 Units per
semester for students and a minimum of six full-time equivalent of staff in each programme,
staff should have a maximum of 15 contact hours per week for lectures, tutorials, practical’s
and supervision of projects.
NUC requirement encourages all academic staff to have PhD degrees; hence appointment
of academic staff is preferably to the Lecturer cadre. Only in exceptional cases are
candidates with great promise appointed to Graduate Assistant and Assistant Lecturer
positions for the purpose of being developed to the Lecturer cadre as registered PhD
candidates.
Academic Support Personnel
Teaching Assistant/Demonstrators to help lecturers in the conduct of tutorials, practical’s
and field work. This category of personnel is not expected to be regular staff as they are to
be paid on the basis of approved hourly rate.
Administrative Support Staff
The services of the administrative support staff are indispensable in the proper
administration of the departments and faculty offices. It is important to recruit very
competent senior staff that are computer literate.
Technical Support Personnel
The services of technical support staff, which are indispensable in the proper running of
laboratories and workshop/studios are required. It is important to recruit very competent
senior technical staff to maintain teaching and research equipment. They are also to
undergo regular training to keep them abreast of developments in equipment operation and
maintenance. The minimum of academic staff to technical staff ratio of 5:1 should be
maintained.
Minimum Number of Staff
Subject to the general standards specified by NUC:
1. there should be a minimum of two PhDs and four M.Eng degree holders full-time academic
staff to mount the programme;
2. each workshop or laboratory should have an adequate number of staff with the right mix,
such that each unit or section in that workshop or laboratory can run efficiently; and
3. there should be an adequate number of administrative staff of the appropriate caliber for
the office of the Head of Department to run.
Student/Staff Ratio
The minimum staff-to-student ratio should be 1:15 from 200 level to 500 level.
Library
In addition to the university and faculty libraries, the programme must have a departmental
library well equipped with specialised books and journals in both physical collections and e-
collections (E-Resources) of various types. Various field and research reports of the
programme must also be available in the library for staff, students and researchers.
The library must be connected to subscribed repository of:
institutions (national and international);
open access sources;
professional bodies’ e-learning platforms, and
relevant international organizations.
The library must also have adequate facilities.
for reading;
provisions for lending, and
reservation unit for specialised materials.
Classrooms, Laboratory, Workshops, Offices and Clinics
Academic and Non-Academic Spaces
The NUC recommends the following physical space requirement:
Academic m2
Professor’s Office 18.50
Head of Department’s Office 18.50
Tutorial Teaching Staff Space 13.50
Other Teaching Staff Space 7.00
Technical Staff Space 7.00
Science Staff Research Laboratory 16.50
Engineering Staff Research Laboratory 14.50
Seminar Space per student 1.85
Drawing Office Space (A.O. Board) (Per Student) 4.60
Drawing Office Space (A.I. Board) (Per Student) 3.70
Laboratory Space 7.50
Non-Academic
Secretarial Space 7.00
Office Accommodation
The requirements for office accommodation are:
1. 13 academic offices.
2. 1 professorial type in the department. Size: each of the office is about 13.5 m
S/No Office No in Room Facilities
1. HOD 1 Table, chairs, A/C, filing cabinet, bookshelves,
computer unit, Secretary and facilities.
2. Professor 1 Table, chairs, A/C, filing cabinet, bookshelves,
computer unit, Secretary and facilities.
3. Reader 1 Table, chairs, A/C, filing cabinet, bookshelves,
computer unit.
4. Senior 1 Table, chairs, A/C, filing cabinet, bookshelves,
Lecturer computer unit.
5. Lecturer I 2 Table, chairs, fan, filing cabinet, bookshelves.
6. Lecturer II 3 Table, chairs, fan, filing cabinet, bookshelves.